適用 LISUN モデル: GNG-B22D、GNG-E27、GNG-G13、GNG-G5

1. 技術基準

GB 1483-2008

IEC 60061-3:2007

2.使用上の注意

Handle with care during use; do not subject the gauge to impact to prevent bending or deformation. Tests must be conducted in strict accordance with standard specifications. Do not use the gauge to inspect lamp holders or sockets with rough or dirty surfaces.

3. Name and Model Number

いいえ。 名前
1 B22/B22d Insertion Gauge 7006-4A-2
2 B22/B22d Clamping Gauge 7006-4B-1
3 B22d Acceptance Gauge 7006-3-1
4 B22/B22d General Specifications 7006 年 11 月 8 日
5 B22/B22d Stop Ring 7006-10-8
6 B22(d) Lamp Socket Torque Gauge IEC 60968, Fig. 3

4.使用説明書

(1) B22/B22d insert gauge (7006-4A-2) (Fig. 1).

Purpose: To verify the insertion fit dimensions of the B22/B22d lamp base relative to the lamp socket in finished lamps.

Instructions for Use: The lamp head should be able to be inserted into the gauge without excessive force until the pin on the lamp head has completely passed through the narrow slot in the gauge.

(2) B22/B22d clamping gauge (7006-4B-1) (Fig. 2).

Purpose: To verify the dimensions related to the secure fit of the lamp base in the socket on the finished lamp.

Instructions for Use: a) Insert the lamp base from the finished lamp into the gauge from the X side until the pin on the lamp base passes through slot Q.

b) Then rotate the lamp base 90° so that one of its pins engages the alignment slot.

c) Next, apply a slight pulling force; the pin will not pass through the Y-face.

d) This test should be performed twice, rotating the lamp 180° to ensure that each pin is tested.

(3) B22d Acceptance Specification (7006-3-1) (Fig. 3).

Purpose: To test the suitability of the automatic wire-insertion process for B22d lamp bases.

Instructions for Use: If the lamp base can be inserted smoothly into the gauge until its contact plate touches the Y-face of the gauge, the lamp base is considered acceptable.

(4) B22/B22d General Specifications (7006-11-8) (Fig. 4)

Purpose: To verify the dimensions Amax, Nmin, D1min, and D1max of the B22/B22d lamp holders on finished lamps, as well as the radial position of the pins.

Instructions for Use: a) Insert the lamp head into the gauge until its pin passes through slot Q.

b) Then rotate the lamp base a very small angle and press it down so that the pin makes tight contact with the S-face.

c) The surface formed at this location should not be lower than the X-surface, nor should it protrude beyond the Z-surface.

(5) B22/B22d Stop Ring (7006-10-8) (Fig. 5)

Purpose: To individually inspect dimension Amin of the B22/B22d lamp bases on finished lamps.

Instructions for Use: If the gauge cannot be slipped onto the lamp base of the finished lamp solely by its own weight, the lamp base shall be considered acceptable.

(6) B22(d) Lamp Socket Torque Gauge (IEC 60968, Fig. 3) (Fig. 6)

Purpose: To test the mechanical strength of B22/B22d lamp bases in accordance with Chapter 8 of IEC 60968 or GB 16844.

Instructions for Use: Screw the torque wrench into the lamp base and apply torque, gradually increasing it from zero to the specified value (3 N·m). After testing, the product meets the relevant requirements.

5. 概略図

“Go” And “Not Go” Gauge For G13 Lamp Cap-Figure1“Go” And “Not Go” Gauge For G13 Lamp Cap-Figure2

図1 図2

“Go” And “Not Go” Gauge For G13 Lamp Cap-Figure3“Go” And “Not Go” Gauge For G13 Lamp Cap-Figure4

図3 図4

“Go” And “Not Go” Gauge For G13 Lamp Cap-Figure5“Go” And “Not Go” Gauge For G13 Lamp Cap-Figure6

図5 図6

Note: The diagrams above are for illustrative purposes only.