3m Semi-Anechoic Chamber | 5m Anechoic Chamber

製品番号: AC-3M

伝言を残す

=
  • 詳細説明
  • ダウンロード
  • Anechoic chambers are divided into semi-anechoic chambers and full-anechoic chambers. They are sealed shielded facilities used to simulate open-field environments for radiated radio interference (EMI) and radiated susceptibility (EMS) testing. Their main structure consists of two parts: first, the shielded chamber, which includes the shielding shell, shielding door, ventilation waveguide windows, and various power filters; second, the absorbing material, mainly composed of ferrite sheets and conical carbon-containing sponge absorbing material. The dimensions of the anechoic chamber must be determined based on the external dimensions of the equipment under test (EUT) and the testing requirements such as the 3-meter method and the 5-meter method.

    当学校区の AC-3M/AC-5M semi-anechoic chamber is a six-sided shielded box, with absorbing material laid on only five sides, and the conductive floor is not covered. This design can simulate the environment of an ideal open field with an “infinitely large, well-conducting ground plane.” Because there is no absorbing material on the ground, a reflection path is formed during testing, and the signal ultimately captured by the receiving antenna is the superposition of the direct path signal and the reflected path signal.

    The AC-F3M/AC-F5M full-anechoic chamber utilizes absorbing materials on all six interior surfaces to significantly reduce interference from external electromagnetic waves on test signals. Furthermore, the absorbing materials weaken reflections from the walls and ceiling, minimizing the impact of multipath effects on test results, thus simulating a free-space environment. Compared to semi-anechoic chambers, the anechoic chamber minimizes reflection interference from the floor, ceiling, and walls.

    仕様:

    LISUN モデル AC-3M AC-F3M AC-5M AC-F5M
    製品名 半無響室 Full-Anechoic Chamber 半無響室 Full-Anechoic Chamber
    Darkroom Outdoor
    寸法(L×W×H)
    9.5 * 6.5 * 6.5m 12.5 * 8.5 * 7.5m
    Quiet Zone and Test Distance QZ=ø2.0m at 3.0m test distance QZ=ø3.0m at 3.0m & 5.0m test distance
    試験周波数範囲 9kHz/30MHz~18GHz
    Types and installation of absorbing materials 半無響室 AC-3M/AC-5M: Except for the ground, the other five surfaces are covered with ferrite tiles + 300/500mm EPP wedges. Additionally, 9㎡ of movable absorbing material is placed on the ground to reduce ground reflection (meeting IEC 61000-4-3:2020 Figure 2 requirements).
    Full-Anechoic Chamber AC-F3M/AC-F5M: Six sides covered with ferrite tiles + 300/500mm EPP wedge-shaped tapers
    Flame retardant rating of
    microwave absorbing Materials
    UL94 V-0 Level,EN 13501-1/DIN 4102 A2 Level
    シールド性能 ≥105dB
    Normalized Site Attenuation NSA:±3.5dB (30MHz to 1GHz)
    Maximum voltage standing
    wave ratio of the site
    SVSWR:+5.5dB(1GHz to 18GHz)
    Field Uniformity Deviation 0dB/+6dB at 75 % of 16 measuring points(26/80MHz to 18GHz)
    電気システム LED lights, distribution boxes, switches, sockets, cables and conduits, etc.
    換気装置 It adopts a honeycomb structure, with dimensions of 400*400mm, and includes an air conditioning interface flange.
    監視システム Withstands 30V/m electric field strength: CCTV high-definition camera, color LCD monitor
    Ground Power Interface Box Dimensions: 300*300*200mm, includes one 220V/10A socket and one 380V/16A interface.
    Wall Adapter Plate Dimensions: 300*300mm, including 6 N-N tubes, 2 SMA-SMA tubes, and 2 waveguides with an inner diameter of 35mm.
    フィルタ Telephone filter, network filter, power supply filter, single-phase power supply 32A and three-phase power supply 32A (voltage consistent with the State Grid).
    その他の装飾材料 White reflector on the wall
    Operating temperature and
    湿度
    15℃~30℃, relative humidity ≤75% (no condensation)
    Earthquake Resistance Level Level8
    規格 IEC 61000-4-3,IEC 61000-4-20,CISPR 16-1-4,ANSI C63.4
    適用可能なテストの種類 EMI/EMS testing for consumer electronics, small household appliances, and small industrial equipment EMI/EMS testing for automotive electronics, large industrial equipment, and communication terminals.
    必要な構成:
    Platform screen door
    LISUN model AC-DR1.5X2M: Pneumatic shielding door size is 1.5*2m. (Other options: AC-DR2X2M pneumatic shielding door size is 2*2m; AC-DR3X3A fully automatic shielding door size is 3*3m; AC-DR4X4A fully automatic shielding door size is 4*4m)
    オプション構成 1:
    Test Turntable
    LISUN model AC-TT3M1.5D0.5T: Turntable diameter 1.5 meters, maximum load capacity 500 kg, 0°~360° continuous rotation, accuracy ±1°. (Other options: AC-TT3M2D1T turntable diameter 2 meters, maximum load capacity 1000 kg; AC-TT5M3D2T turntable diameter 3 meters, maximum load capacity 2000 kg; AC-TT5M3D5T turntable diameter 3 meters, maximum load capacity 5000 kg)
    オプション構成 2:
    アンテナタワー
    LLISUN AC-AT4MS model: Single-axis antenna tower, 4-meter height electrically raised, includes controller for tower and turntable operation. (Other options: AC-AT4MD dual-axis antenna tower, 4-meter height electrically raised, adjustable pitch angle)
    オプション構成 3:
    制御室
    LISUN AC-CT3M model: 3*3*3m (other options available: AC-CT5M, 4*3*3m). Designed for housing and testing all EMI and EMS testing instruments. The shielded door is 1.2*2m in size and includes the electrical system, ventilation system, ground power interface box, wall interface panel, and filters.
    オプション構成 4:
    Amplifier Room
    LISUN AC-PA3M model: 3*3*3m (other options available: AC-PA5M, 4*3*3m). Used to shield high-power amplifiers from electromagnetic interference and radio frequency radiation, protecting test personnel and equipment. The shielded door is 1.2*2m in size and includes the electrical system, ventilation system, ground power interface box, wall interface board, and filters.
    注意:
    1. The maximum size of the device under test (DUT) is determined by the size of the shielding door and the size of the quiet zone (QZ);
    2. LISUN can customize semi-anechoic chambers or fully anechoic chambers of other sizes according to customer requirements.
    AC-3M/AC-F3M Anechoic Chamber Layout Design

    AC-3M/AC-F3M Anechoic Chamber Layout Design

    AC-5M/AC-F5M Anechoic Chamber Layout Design

    AC-5M/AC-F5M Anechoic Chamber Layout Design

    EMCにはEMIとEMSが含まれる

    EMCにはEMIとEMSが含まれる

    典型的なアプリケーション1:無響室は、電磁感受性(EMS)の放射感受性(RS、または放射イミュニティ)の完全コンプライアンステストに使用されます(LISUN 型式:AC-EMS)
    無響室は信号源、電力計、等方性電界センサー、電力増幅器を備えており、 IEC 61000-4-3、GB/T 17626.3 および GB/T 17215 規格の電磁感受性 (EMS) および放射感受性 (RS) 完全コンプライアンス テスト。
    LISUN モデル 製品名 製品仕様
    LS-SMB100B 信号発生器 9kHz~6GHz、AC電源 - ACアダプター
    LS-GLJ06G パワーメータ 9kHz~6GHz(2セット必要: 1つは出力を測定し、もう1つは入力を測定します)
    LS-PB60 電界強度プローブとモニター 1MHz~6GHz、600V/m
    LS-PA80M1G-300W パワーアンプ 80MHz~1GHz、定格出力300W以上、アラーム機能付き、5Uシャーシ
    LS-PA1G6G-120W 1GHz~6GHz、定格出力120W以上、アラーム機能付き、4Uシャーシ
    LS-9128ESP スタック型ログペリオディックアンテナ 周波数: 30MHz~1GHz; 最大出力3kW; 入力インピーダンス50Ω; VSWR<1.5:1
    LS-9120D ダブルリッジ広帯域ホーンアンテナ 周波数:1GHz〜8GHz、ゲイン6〜17dBi、電力200W、定在波≤2.5
    CASE-19  キャビネット 上記の機器をキャビネットに設置すると、見た目がすっきりしてプロフェッショナルになり、操作も簡単で便利になります。
    LS-SOFT61000-3 ソフトウェア IEC/EN 61000-4-3に準拠した設計 LISUN
    PC-3 Windowsシステム搭載PC ACERまたは類似ブランドのコンピュータとモニター
    LS-SW03  RFスイッチ(オプション) 2台または3台のパワーアンプを簡単に切り替え可能。3チャンネル。コネクタ:SMA。インピーダンス:50Ω。周波数範囲:DC~6GHz。寿命:1,000,000サイクル
    EMS Radiation Susceptibility Testing System

    EMS Radiation Susceptibility Testing System

    典型的なアプリケーション2:無響室は、伝導放出(CE)および放射放出(RE)の完全コンプライアンステストの電磁干渉(EMI)に使用されます(LISUN 型式:AC-EMI)
    無響室はR&S受信機システムと連携して動作し、 IEC 61000-3-2、IEC 61000-3-3、IEC 61000-6-4、CISPR 11、CISPR 14、CISPR 16-1-4、CISPR 16-2-3、CISPR 20、CISPR 22、CISPR25、および CISPR 32。

    LISUN モデル 製品名 ブランド 製品仕様
    ESRP7 EMIテストレシーバー  R&S CISPR 16-1-1 に準拠し、9 kHz ~ 7.2 GHz の完全コンプライアンス テストに合格しています (オプションの ESRP 3: 9 kHz ~ 3.6 GHz)。
    eps 216 人工の力 R&S 周波数範囲: 9 kHz ~ 30 MHz。最大 16 A の電力処理能力 (国/地域により異なります) シミュレーション インピーダンス (50 μH + 5 Ω) || 50 Ω、CISPR 16-1-2 に準拠 V 字型ネットワークは CISPR、EN、EN、EN、VDE、ANSI、FCC Part 15 および MIL-STD-461 に準拠、CISPR 16-1-2 に従って校正済み
    VTSD9561FN ダイオードパルスリミッタ  シュヴァルツベック ダイオードパルスリミッター+10 dB減衰、ヒューズランプ、入力Nメス、出力Nオス。
    VULB 9168 TRILOG ブライトバンドアンテナ シュヴァルツベック TRILOGスーパーブロードバンド試験用アンテナ、(25)30-1000(2000)MHz、10W、幅縮小、直径<1.5m。
    BBHA 9120D ダブルリッジ広帯域ホーンアンテナ シュヴァルツベック 広帯域ホーンアンテナ(0,8)1-18GHz、Nコネクタ
    CASE-19 キャビネット LISUN 上記の機器をキャビネットに設置すると、見た目がすっきりしてプロフェッショナルになり、操作も簡単で便利になります。
    LS-E3-EMI テストライン、ソフトウェア、システム統合 LISUN カスタム高周波ケーブル、EMI テスト ソフトウェア、機器のデバッグと設置、トレーニング。
    PC-3 Windowsシステム搭載PC ACER またはACERの類似ブランドのコンピュータとモニター
    タグ:
  • AC-3M 3m電波暗室パンフレット IEC 61000-4-3:2020規格の無料ダウンロード